1.
Hematol Transfus Cell Ther ; 46 Suppl 1: S32-S39, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38582746

RESUMO

Hemostasis plays a critical role in surgical procedures and is essential for a successful outcome. Advances in hemostatic agents offer new approaches to controlling bleeding thereby making surgeries safer. The appropriate choice of these agents is crucial. Volume replacement, another integral part of Patient Blood Management (PBM), maintains adequate tissue perfusion, preventing cellular damage. Individualization in fluid administration is vital with the choice between crystalloids and colloids depending on each case. Colloids, unlike crystalloids, increase oncotic pressure, contributing to fluid retention in the intravascular space. Understanding these aspects is essential to ensure safe and effective surgery, minimizing complications related to blood loss and maintaining the patient's hemodynamic status.

2.
Clin Oral Investig ; 28(5): 244, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38583113

RESUMO

OBJECTIVES: To compare oral adhesive bandages with the classic compression method and evaluate the clinical efficacy of this wound dressing material in improving postoperative comfort, wound healing, and hemostasis in tooth extraction. MATERIALS AND METHODS: The study was designed as a randomized controlled clinical trial. A total of 120 patients were recruited and randomly assigned to the study group and the control group. In the study group, oral adhesive bandages were used as wound dressing. In the control group, patients bit on cotton balls and gauze, as usual. Hemorrhage, comfort, and healing levels were evaluated at postoperative 1 h, 24 h, and 7 days. The adhesion time of the oral adhesive bandages was also recorded. RESULTS: The average adhesion time of the oral adhesive bandages was 26.6 h. At postoperative 1 and 24 h, the hemostatic levels of the oral adhesive bandage group were significantly higher than those of the control group. The oral adhesive bandage group also reported significantly higher comfort scores than the control group. Both groups had similar healing levels and side effects. But the mean score for wound healing was slightly higher in the oral adhesive bandage group. CONCLUSIONS: Oral adhesive bandages were more effective than cotton balls and gauze in providing hemostatic and comfort effects on extraction wounds. CLINICAL RELEVANCE: Oral adhesive bandages possess clinical value in the management of extraction wounds.


Assuntos
Hemostáticos , Humanos , Hemostáticos/uso terapêutico , Bandagens , Extração Dentária , Assistência Odontológica , Hemostasia
3.
Obstet Med ; 17(1): 13-21, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38660318

RESUMO

Background: Concerns about COVID-19-associated coagulopathy (CAC) in pregnant individuals were raised in early pandemic. Methods: An ISTH-sponsored COVID-19 coagulopathy in pregnancy (COV-PREG-COAG) international registry was developed to describe incidence of coagulopathy, VTE, and anticoagulation in this group. Results: All pregnant patients with COVID-19 from participating centers were entered, providing 430 pregnancies for the first pandemic wave. Isolated abnormal coagulation parameters were seen in 20%; more often with moderate/severe disease than asymptomatic/mild disease (49% vs 15%; p < 0.0001). No one met the ISTH criteria for disseminated intravascular coagulopathy (DIC), though 5/21 (24%) met the pregnancy DIC score. There was no difference in antepartum hemorrhage (APH) with asymptomatic/mild disease versus moderate/severe disease (3.4% vs 7.7%; p = 0.135). More individuals with moderate/severe disease experienced postpartum hemorrhage (PPH) (22.4% vs 9.3%; p = 0.006). There were no arterial thrombotic events. Only one COVID-associated venous thromboembolism (VTE) was reported. Conclusions: Low rates of coagulopathy, bleeding, and thrombosis were observed among pregnant people in the first pandemic wave.

4.
Curr Oncol ; 31(4): 1994-2023, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38668052

RESUMO

Melatonin is a multifunctional hormone regulator that maintains homeostasis through circadian rhythms, and desynchronization of these rhythms can lead to gastrointestinal disorders and increase the risk of cancer. Preliminary clinical studies have shown that exogenous melatonin alleviates the harmful effects of anticancer therapy and improves quality of life, but the results are still inconclusive due to the heterogeneity of the studies. A personalized approach to testing clinical parameters and response to integrative treatment with nontoxic and bioavailable melatonin in patient-centered N-of-1 studies deserves greater attention. This clinical case of colon cancer analyzes and discusses the tumor pathology, the adverse effects of chemotherapy, and the dynamics of markers of inflammation (NLR, LMR, and PLR ratios), tumors (CEA, CA 19-9, and PSA), and hemostasis (D-dimer and activated partial thromboplastin time). The patient took melatonin during and after chemotherapy, nutrients (zinc, selenium, vitamin D, green tea, and taxifolin), and aspirin after chemotherapy. The patient's PSA levels decreased during CT combined with melatonin (19 mg/day), and melatonin normalized inflammatory markers and alleviated symptoms of polyneuropathy but did not help with thrombocytopenia. The results are analyzed and discussed in the context of the literature on oncostatic and systemic effects, alleviating therapy-mediated adverse effects, association with survival, and N-of-1 studies.


Assuntos
Neoplasias do Colo , Melatonina , Humanos , Melatonina/uso terapêutico , Neoplasias do Colo/tratamento farmacológico , Masculino , Pessoa de Meia-Idade , Oncologia Integrativa/métodos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Feminino
5.
Artigo em Inglês | MEDLINE | ID: mdl-38638286

RESUMO

We herein describe a 49-year-old man with severe heart failure due to fulminant myocarditis who underwent left ventricular assist device implantation and received clopidogrel and warfarin as antithrombotic agents. The patient developed anemia secondary to chronic bleeding gastric hyperplastic polyps, necessitating endoscopic mucosal resection. Despite attempts to manage post-endoscopic mucosal resection bleeding from a gastric ulcer by endoscopic hemostasis using hemostatic forceps, local hemostatic agents, and polyglycolic acid sheets, the bleeding persisted. Hemostasis of the refractory bleeding was finally achieved by endoscopic hand-suturing of the ulcer. One month later, the ulcer was almost completely scarred. This case has important clinical value in that it demonstrates the efficacy of endoscopic hand-suturing even in challenging cases such as refractory bleeding gastric ulcers in patients with left ventricular assist devices.

6.
J Surg Res ; 298: 316-324, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38640617

RESUMO

INTRODUCTION: Intraoperative blood loss and postoperative hemorrhage affect outcomes after liver resection. GATT-Patch is a new flexible, pliable hemostatic sealant patch comprising fibrous gelatin carrier impregnated with N-hydroxy-succinimide polyoxazoline. We evaluated safety and performance of the GATT-Patch for hemostasis at the liver resection plane. METHODS: Adult patients undergoing elective open liver surgery were recruited in three centers. GATT-Patch was used for minimal to moderate bleeding at the liver resection plane. The primary endpoint was hemostasis of the first-treated bleeding site at 3 min versus a prespecified performance goal of 65.4%. RESULTS: Two trial stages were performed: I (n = 8) for initial safety and II (n = 39) as the primary outcome cohort. GATT-Patch was applied in 47 patients on 63 bleeding sites. Median age was 60.0 (range 25-80) years and 70% were male. Most (66%) surgeries were for colorectal cancer metastases. The primary endpoint was met in 38 out of 39 patients (97.4%; 95% confidence interval: 84.6%-99.9%) versus 65.4% (P < 0.001). Of all the 63 bleeding sites, hemostasis was 82.7% at 30, 93.7% at 60, and 96.8% at 180 s. No reoperations for rebleeding or device-related issues occurred. CONCLUSIONS: When compared to a performance goal derived from state-of-the-art hemostatic agents, GATT-Patch for the treatment of minimal to moderate bleeding during liver surgery successfully and quickly achieved hemostasis with acceptable safety outcomes. (ClinicalTrials.gov Identifier: NCT04819945).

7.
Int J Biol Macromol ; : 131642, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38641283

RESUMO

To better treat bacteria-infected wounds and promote healing, new wound dressings must be developed. In this study, we obtained PA@Fe by chelating iron trivalent ions (Fe3+) with protocatechualdehyde (PA), which has a catechol structure. Subsequently, we reacted it with ethylene glycol chitosan (GC) via a Schiff base reaction and loaded vancomycin to obtain an antibacterial Gel@Van hydrogel with a photothermal response. The as-prepared Gel@Van hydrogel exhibited good injectability, self-healing, hemostasis, photothermal stability, biocompatibility, and antioxidant and antibacterial properties. Moreover, Gel@Van hydrogel achieved highly synergistic antibacterial efficacy through photothermal and antibiotic sterilization. In a mouse skin-damaged infection model, Gel@Van hydrogel had a strong ability to promote the healing of methicillin-resistant Staphylococcus aureus (MRSA)-infected wounds, indicating the great potential application value of Gel@Van hydrogel in the field of treating and promoting the healing of infected wounds.

8.
Int J Biol Macromol ; : 131399, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38641504

RESUMO

Developing an injectable hemostatic dressing with shape recovery and high blood absorption ratio for rapid hemostasis in noncompressible hemorrhage maintains a critical clinical challenge. Here, double-network cryogels based on carboxymethyl chitosan, sodium alginate, and methacrylated sodium alginate were prepared by covalent crosslinking and physical crosslinking, and named carboxymethyl chitosan/methacrylated sodium alginate (CM) cryogels. Covalent crosslinking was achieved by methacrylated sodium alginate in the freeze casting process, while physical crosslinking was realized by electrostatic interaction between the amino group of carboxymethyl chitosan and the carboxyl group of sodium alginate. CM cryogels exhibited large water swelling ratios (8167 ± 1062 %), fast blood absorption speed (2974 ± 669 % in 15 s), excellent compressive strength (over 160 kPa for CM100) and shape recovery performance. Compared with gauze and commercial gelatin sponge, better hemostatic capacities were demonstrated for CM cryogel with the minimum blood loss of 40.0 ± 8.9 mg and the lowest hemostasis time of 5.0 ± 2.0 s at hemostasis of rat liver. Made of natural polysaccharides with biocompatibility, hemocompatibility, and cytocompatibility, the CM cryogels exhibit shape recovery and high blood absorption rate, making them promising to be used as an injectable hemostatic dressing for rapid hemostasis in noncompressible hemorrhage.

9.
Biochem Biophys Res Commun ; 712-713: 149946, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38643717

RESUMO

Platelets are small anucleate cells that play a key role in thrombosis and hemostasis. Our group previously identified apolipoprotein A-IV (apoA-IV) as an endogenous inhibitor of thrombosis by competitive blockade of the αIIbß3 integrin on platelets. ApoA-IV inhibition of platelets was dependent on the N-terminal D5/D13 residues, and enhanced with absence of the C-terminus, suggesting it sterically hinders its N-terminal platelet binding site. The C-terminus is also the site of common apoA-IV polymorphisms apoA-IV-1a (T347S) and apoA-IV-2 (Q360H). Interestingly, both are linked with an increased risk of cardiovascular disease, however, the underlying mechanism remains unclear. Here, we generated recombinant apoA-IV and found that the Q360H or T347S polymorphisms dampened its inhibition of platelet aggregation in human platelet-rich plasma and gel-filtered platelets, reduced its inhibition of platelet spreading, and its inhibition of P-selectin on activated platelets. Using an ex vivo thrombosis assay, we found that Q360H and T347S attenuated its inhibition of thrombosis at both high (1800s-1) and low (300s-1) shear rates. We then demonstrate a conserved monomer-dimer distribution among apoA-IV WT, Q360H, and T347S and use protein structure modelling software to show Q360H and T347S enhance C-terminal steric hindrance over the N-terminal platelet-binding site. These data provide critical insight into increased cardiovascular risk for individuals with Q360H or T347S polymorphisms.

12.
Biochemistry (Mosc) ; 89(Suppl 1): S14-S33, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38621742

RESUMO

Reactive oxygen species (ROS) are constantly generated in a living organism. An imbalance between the amount of generated reactive species in the body and their destruction leads to the development of oxidative stress. Proteins are extremely vulnerable targets for ROS molecules, which can cause oxidative modifications of amino acid residues, thus altering structure and function of intra- and extracellular proteins. The current review considers the effect of oxidation on the structural rearrangements and functional activity of hemostasis proteins: coagulation system proteins such as fibrinogen, prothrombin/thrombin, factor VII/VIIa; anticoagulant proteins - thrombomodulin and protein C; proteins of the fibrinolytic system such as plasminogen, tissue plasminogen activator and plasminogen activator inhibitor-1. Structure and function of the proteins, oxidative modifications, and their detrimental consequences resulting from the induced oxidation or oxidative stress in vivo are described. Possible effects of oxidative modifications of proteins in vitro and in vivo leading to disruption of the coagulation and fibrinolysis processes are summarized and systematized, and the possibility of a compensatory mechanism in maintaining hemostasis under oxidative stress is analyzed.


Assuntos
Hemostasia , Ativador de Plasminogênio Tecidual , Ativador de Plasminogênio Tecidual/metabolismo , Espécies Reativas de Oxigênio , Coagulação Sanguínea , Fatores de Coagulação Sanguínea/metabolismo , Estresse Oxidativo
13.
Surg Endosc ; 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630180

RESUMO

BACKGROUND: The use of hemostatic agents by general surgeons during abdominal operations is commonplace as an adjunctive measure to minimize risks of postoperative bleeding and its downstream complications. Proper selection of products can be hampered by marginal understanding of their pharmacokinetics and pharmacodynamics. While a variety of hemostatic agents are currently available on the market, the choice of those products is often confusing for surgeons. This paper aims to summarize and compare the available hemostatic products for each clinical indication and to ultimately better guide surgeons in the selection and proper use of hemostatic agents in daily clinical practice. METHODS: We utilized PubMed electronic database and published product information from the respective pharmaceutical companies to collect information on the characteristics of the hemostatic products. RESULTS: All commercially available hemostatic agents in the US are described with a description of their mechanism of action, indications, contraindications, circumstances in which they are best utilized, and expected results. CONCLUSION: Hemostatic products come with many different types and specifications. They are valuable tools to serve as an adjunct to surgical hemostasis. Proper education and knowledge of their characteristics are important for the selection of the right agent and optimal utilization.

14.
Rev Gastroenterol Mex (Engl Ed) ; 89(1): 144-162, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38600006

RESUMO

Coagulation management in the patient with cirrhosis has undergone a significant transformation since the beginning of this century, with the concept of a rebalancing between procoagulant and anticoagulant factors. The paradigm that patients with cirrhosis have a greater bleeding tendency has changed, as a result of this rebalancing. In addition, it has brought to light the presence of complications related to thrombotic events in this group of patients. These guidelines detail aspects related to pathophysiologic mechanisms that intervene in the maintenance of hemostasis in the patient with cirrhosis, the relevance of portal hypertension, mechanical factors for the development of bleeding, modifications in the hepatic synthesis of coagulation factors, and the changes in the reticuloendothelial system in acute hepatic decompensation and acute-on-chronic liver failure. They address new aspects related to the hemorrhagic complications in patients with cirrhosis, considering the risk for bleeding during diagnostic or therapeutic procedures, as well as the usefulness of different tools for diagnosing coagulation and recommendations on the pharmacologic treatment and blood-product transfusion in the context of hemorrhage. These guidelines also update the knowledge regarding hypercoagulability in the patient with cirrhosis, as well as the efficacy and safety of treatment with the different anticoagulation regimens. Lastly, they provide recommendations on coagulation management in the context of acute-on-chronic liver failure, acute liver decompensation, and specific aspects related to the patient undergoing liver transplantation.


Assuntos
Insuficiência Hepática Crônica Agudizada , Transtornos da Coagulação Sanguínea , Humanos , Insuficiência Hepática Crônica Agudizada/complicações , Transtornos da Coagulação Sanguínea/complicações , Transtornos da Coagulação Sanguínea/terapia , Cirrose Hepática/complicações , Cirrose Hepática/terapia , Coagulação Sanguínea , Hemostasia
15.
Cureus ; 16(2): e55141, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38558664

RESUMO

BACKGROUND: Incidence of sternal dehiscence, wound infection, and mortality are prevalent following sternotomy. Bone wax is widely used over the sternal edges for augmenting hemostasis. This study evaluated the clinical equivalence of Truwax® (Healthium Medtech Limited, Bengaluru, India) with Ethicon® (Johnson & Johnson, New Brunswick, New Jersey, United States) bone wax for sternal wound hemostasis in subjects undergoing surgical procedures by sternotomy. METHODS: The primary endpoint of this prospective (May 2022-April 2023), parallel-group, two-arm, randomized, single-blind, multicenter study was to evaluate the proportion of subjects having sternal dehiscence within 26 weeks of median sternotomy closure. Secondary endpoints assessed the average time to hemostasis on sternum sides, bone wax properties, number of dressing changes, sternal bone instability (clinically/chest radiography), pain, perioperative/postoperative complications, blood and blood products used, duration of intensive care unit (ICU)/hospital stay, reoperations, time taken to return back to work and normal day-to-day activities, subject satisfaction and quality of life (QoL), and adverse events. A probability of <0.05 was considered significant. RESULTS: No incidence of sternal dehiscence or postoperative complications was witnessed. Time to hemostasis, bone wax properties, number of dressing changes, sternal stability, pain, blood and blood products used, duration of ICU/hospital stay, reoperations, time taken to return back to normal day-to-day activities and to work, and subject satisfaction and QoL were comparable between Truwax® and Ethicon® bone wax groups. CONCLUSION: Truwax® and Ethicon® bone waxes are safe and effective and provide sternal wound hemostasis in people undergoing sternotomy.

16.
Mater Today Bio ; 26: 101031, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38558772

RESUMO

Developing a self-elastic sponge integrating active and passive hemostatic mechanisms for the effective management of uncontrolled coagulopathic hemorrhage remains a challenge. We here developed a chitosan-based sponge by integrating freeze-drying, chemical decoration of alkyl chains and phosphate groups, and physical loading of thrombin. The sponge exhibited high mechanical strength, self-elasticity, and rapid shape recovery. The sponge facilitated blood cell adhesion, aggregation, and activation through hydrophobic and electrostatic interactions, as well as accelerated blood clotting. The sponge exhibited higher efficacy than commercial gauze and gelatin sponge in managing uncontrolled hemorrhage from heparinized rat tail amputation, liver superficial injury, and liver perforating wound models. In addition, the sponge exhibited favorable biodegradability and biocompatibility. These findings revealed that the developed sponge holds great potential as a novel hemostat for effectively managing uncontrolled coagulopathic hemorrhage from superficial and perforating wounds.

17.
Transfusion ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38566492

RESUMO

INTRODUCTION: The VCM is a point-of-care analyzer using a new viscoelastometry technique for rapid assessment of hemostasis on fresh whole blood. Its characteristics would make it suitable for use in austere environments. The purpose of this study was to evaluate the VCM in terms of repeatability, reproducibility and interanalyzer correlation, reference values in our population, correlation with standard coagulation assays and platelet count, correlation with the TEG5000 analyzer and resistance to stress conditions mimicking an austere environment. METHODS: Repeatability, reproducibility, and interanalyzer correlation were performed on quality control samples (n = 10). Reference values were determined from blood donor samples (n = 60). Correlations with standard biological assays were assessed from ICU patients (n = 30) and blood donors (n = 60) samples. Correlation with the TEG5000 was assessed from blood donor samples. Evaluation of vibration resistance was performed on blood donor (n = 5) and quality control (n = 5) samples. RESULTS: The CVs for repeatability and reproducibility ranged from 0% to 11%. Interanalyzer correlation found correlation coefficients (r2) ranging from 0.927 to 0.997. Our reference values were consistent with those provided by the manufacturer. No robust correlation was found with conventional coagulation tests. The correlation with the TEG5000 was excellent with r2 ranging from 0.75 to 0.92. Resistance to stress conditions was excellent. CONCLUSION: The VCM analyzer is a reliable, easy-to-use instrument that correlates well with the TEG5000. Despite some logistical constraints, the results suggest that it can be used in austere environments. Further studies are required before its implementation.

18.
Indian J Otolaryngol Head Neck Surg ; 76(2): 1886-1890, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38566718

RESUMO

The primary function of nasal packs is to modulate the bleeding, prevent adhesions and obstruction, with least discomfort to the subjects without risking secondary infection. However, both packing and removal of the pack is an unpleasant experience, with the latter being extremely painful. Therefore the need of the hour is a dressing which prioritizes subject comfort without compromising other desired nasal pack properties. Twenty subjects were enrolled in this interventional, open label study. The subjects had 10 hospital visits, starting from baseline (Visit 1) to postoperative day 28 (Visit 10), at regular intervals. The proportion of the population with postoperative pain alleviation and bleeding control failure (within 10 min) were the main objectives. Within 10 min of VELNEZ administration, all 20 participants got their bleeding under control. With VELNEZ, the painful nasal pack removal method was totally avoided because it was biodegradable. No moderate/severe pain, infection and adhesions were reported in any of the subjects, but few subjects reported moderate obstruction until Visit 3 (Discharge Day). In the present study, for participants undergoing nasal surgery, VELNEZ proved to be a secure and reliable nasal pack. Trial Registration: CTRI/2021/09/036437, prospectively registered.

19.
Neurospine ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575113

RESUMO

Objective: To demonstrate the non-inferiority of the novel hemostatic agent, Hemofence® (BMI Korea Co. Ltd., Jeju Korea, thrombin cross-linked sodium hyaluronate gel matrix) compared to the established agent, Floseal Hemostatic Matrix (Baxter, thrombin-gelatin matrix) in achieving hemostasis for spinal surgeries, with secondary objectives to assess additional efficacy and safety. Methods: This clinical trial was a multicenter, randomized, subject-blinded, active-controlled, parallel-group, phase 3 study. Investigational drugs were administered to the first and second bleeding sites of each participant (or only to the first site if a second site was absent), evaluating hemostasis success rate within 10 minutes and the time to achieve hemostasis. Subsequent visits were conducted for safety assessments. For non-inferiority test, a 97.5% one-sided confidence interval was used; the test group was deemed non-inferior if the lower limit exceeded -10%. Results: This trial showed a 97.10% success rate in the test group and 96.05% in the control group for primary efficacy. The 95% confidence interval (-4.90%, 7.44%) confirmed the test drug's non-inferiority. Time to hemostasis showed no significant difference between groups. All adverse events, adverse drug reactions, and serious adverse events were statistically similar between groups (p=1.0000, p=0.2427, and p=0.9663, respectively). Conclusion: A novel hemostatic agent, Hemofence®, demonstrated an efficacy and safety profile comparable to that of Floseal.

20.
Artigo em Inglês | MEDLINE | ID: mdl-38581551

RESUMO

Non-activated four-factor prothrombin complex concentrate (4 F-PCC) has emerged as the preferred reversal strategy for patients on warfarin with life-threatening bleeding. Current dosing recommendations for 4 F-PCC require pre-treatment international normalized ratio (INR) and bodyweight values, resulting in ordering and administration delays. Studies have shown that alternative dosing regimens are safe and efficacious. This retrospective, single-center, pre- and post-protocol analysis was conducted to assess the efficacy of a pharmacist driven modified fixed-dose 4 F-PCC regimen versus package insert weight- and INR-based dosing regimen for warfarin reversal. The primary outcome was achievement of INR less than two. Secondary outcomes included dose and cost of 4 F-PCC, a time analysis, incidence of concomitant vitamin K administration, and incidence of thrombosis within seven days of 4 F-PCC. There were 195 patients included in the analysis, with 74 in the pre-cohort and 121 in the post-cohort. Baseline characteristics were similar between cohorts with the most common indication for warfarin use being atrial fibrillation (48.6% versus 47.1%) and reversal being intracerebral hemorrhage (68.9% versus 43.0%). Achievement of the primary endpoint occurred in 92% versus 95% (p = 0.097) of patients. A statistically significant difference was seen between cohorts regarding median dose and cost of 4 F-PCC administered (p < 0.001). Eleven thromboembolic events occurred with three events in the pre-cohort and eight events in the post-cohort (p = 0.453). A fixed-dose of 1500IU of 4 F-PCC was effective in reversing INR to less than two in most patients regardless of reversal indication with minimal thrombotic risks.